Specifications
Safe Overload |
150%RC |
Rated Output |
1.5mV/V±1% |
Nonlinearity |
0.15%RO |
Hysteresis |
0.15%RO |
Repeatability |
0.1%RO |
Excitation Voltage |
10V (or less) |
Safe Excitation Voltage |
15V |
Input Rsistance |
350Ω |
Output Rsistance |
350Ω |
Compensated Temp.Range |
-10 to 60℃ |
Safe Temp.Range |
-30 to 80℃ |
Temp.Effect on Zero |
0.01%RO/℃ |
Temp.Effect on Output |
0.01%/℃ |
Connector(on body) |
Receptacle / PRC03-21A10-7F |
Attached cable |
L-A-5 (Refer to transducer connections) |
REMARKS:
Load cells of this Model can also be applied to a compression use although Model RTB load cells of standard version are supplied with a calibration data sheet treating data to tension direction only.
We can say from our back data of this Model that its tension sensitivity and compression sensitivity are almost the same each other, namely, within 0.2 %, but we can willingly effect a compression load test to this Model whenever necessary on extra cost.
Instruction Manual・・・・・This project is under planning. Please call on us for details, if necessary.
All the instruction nanuals are of Portable Documents Formats. For reading the instruction manual, it is necessary to be installed yourself in the Adobe Reader of Adobe Company. Adobe Reader is the registered trademark of Adobe Systems Co., Ltd.