strain gage animation

Japanese

"AE801" / Semiconductor Transducer Element

semiconductor transducer elements

   OUTLINES

Semiconductor Strain Gage Transducer Elements Model "AE801" are those having been subjected to a strict and a very careful selection among 800 Series manufactured by AME (AKSJESELSKAPET MICRO-ELEKTRONIKK ) in Norway. These are very unique and highly sensitive transducr elements in converting physical amount of force, pressure, displacement, acceleration, angle and so on into precisely corresponding electrical signals. The transducer-element consists of two main parts,the beam itself and the header to which the beam is mounted. The beam, which is made of single-crystal silicon, has one diffused resister on each side. The resister, which are of the p-type, are manufactured in the same way as transister by the oxide-masking technique. In order to provide a creepfree mounting of the beam, on alloying technique has been developed which join the four pins of the header to contact areas which terminate each resister. Thus the four pins in the header serve both as a mechanical mounting for the beam and electrical connections for the resister. This way of mounting the beam been patented.

Features & Applications

Specifications

[Sensor Parameters]    
Voltage Excitation   1 - 10 DC or AC
Recommended Voltage Excitation   <6V
Resister value   1000 兌亇25%
Resister matching   亇10 亾
Deflection of the beam at full scale (FS)   Typical 70 兪m
Load at tip of beam at FS   0.12 N
Safe overload   120 % of FSO
[Signal Parameters 25亷]    
Full scale output (FSO)   30 mV/V亇30 亾
Gauge factor of individual resister   55 - 70
Non-Linearity (typical)   亇0.25 % FSO
Hysteresis (typical)   亇0.10 % FSO
Temp.increase by internal power dissipation   0.25 亷/mW in oil,1亷/mW in air
Breakdown voltage between resisters   1 min 15 V
[Environmental Parameters]    
Temperature range (operation and storage)   -55 亷 to +125 亷
Temperature coefficient of individual resister   0.8亊10-3/亷亇25 %
Thermal zero shift   亇0.02 % FSO/亷
Thermal sensitivity shift   -0.17亇0.05 %/亷
Natural frequency (in air)   ~12 kHz
[Electrical insulation]    
Isolation voltage between header and leads   1 min 200 V DC
[Mechanical data]    
Modulus of elasticity (typical)   1.6亊105/mm2
Spring constant at full length   2 N/mm
Weight approx.   120 mg
Natural frequency (in air)   7 kHz approx.
[Dimension in mm]    
Case length   5 mm
Case diameter   兂1.8 mm
Beam length   5 mm
Width   1 mm
Thickness   0.15 mm

Measuring Circuit

AE801 measuring circuit

Unbalanced output at no load can be cancelled provided that a balancing resistor "Ry" is inserted into one side of Transducer Element Strain Gage Bridge. Refer to a separate bulletin entitled "AE801" Technical Information. Also contact our regional office for further questions, if any.

get_adobe_reader